Ajou University repository

Rapid and receptor-free Prussian blue electrochemical sensor for the detection of pathogenic bacteria in blood
Citations

SCOPUS

2

Citation Export

Publication Year
2025-06-01
Journal
Bioelectrochemistry
Publisher
Elsevier B.V.
Citation
Bioelectrochemistry, Vol.163
Keyword
Bacteria detectionBacteria growth monitoringBlood-based diagnosisElectrochemical sensorPrussian blue
Mesh Keyword
Bacteria detectionBacteria growth monitoringBacterium growthBlood-based diagnoseE. coliElectrochemicalsGrowth monitoringP.aeruginosaPrussian blueScreen-printed carbon electrodesBacteriaBiosensing TechniquesElectrochemical TechniquesElectrodesFerrocyanidesHumansLimit of Detection
All Science Classification Codes (ASJC)
BiophysicsPhysical and Theoretical ChemistryElectrochemistry
Abstract
Bloodstream bacterial infections, a major health concern due to rising sepsis rates, require prompt, cost-effective diagnostics. Conventional methods, like CO2-based transduction, face challenges such as volatile metabolites, delayed gas-phase signaling, and the need for additional instruments, whereas electrochemical sensors provide rapid, sensitive, and efficient real-time detection. In this study, we developed a bioreceptor-free Prussian blue (PB) sensor platform for real-time bacterial growth monitoring in blood culture. PB thin films were electrodeposited onto a screen-printed carbon electrode (SPCE) via cyclic voltammetry (CV) technique under optimal conditions. The electrochemical performance of PB/SPCE was assessed using differential pulse voltammetry (DPV) against exoelectrogenic bacteria, including E. coli, P. aeruginosa, S. aureus, and E. faecalis. The proposed sensor exhibited surface-controlled electrochemical kinetics and bacteria-driven metal reduction from PB to Prussian white (PW), facilitated by extracellular electron transfer (EET). It showed significant sensitivity with an extensive detection range of 102–108 CFU/mL for E. coli and S. aureus, and 103–108 CFU/mL for P. aeruginosa and E. faecalis, with reliable detection limits. The sensor accessed the viability of the pathogen within 3 hrs, offering a rapid, efficient alternative to traditional, labor-intensive methods for blood-based diagnostics.
ISSN
1878-562X
Language
eng
URI
https://aurora.ajou.ac.kr/handle/2018.oak/38418
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85214452883&origin=inward
DOI
https://doi.org/10.1016/j.bioelechem.2025.108902
Journal URL
https://www.sciencedirect.com/science/journal/15675394
Type
Article
Show full item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Choi, Jung Il Image
Choi, Jung Il최정일
Department of Mechanical Engineering
Read More

Total Views & Downloads

File Download

  • There are no files associated with this item.