Boiling heat transfer with a microporous heating surface in a narrow gap with cover plates of different wettability
  • Rukhsar, Aqsa ;
  • Fadda, Dani ;
  • Lee, Jungho ;
  • You, Seung M.
Citations

SCOPUS

1

Citation Export

Publication Year
2025-07-01
Journal
International Journal of Heat and Mass Transfer
Publisher
Elsevier Ltd
Citation
International Journal of Heat and Mass Transfer, Vol.244
Keyword
Boiling heat transferCover plate wettabilityHydrophilicHydrophobicMicroporous coatingNarrow gap
Mesh Keyword
Boiling heat transferCover plateCover plate wettabilityHeating surfacesHydrophilicsHydrophobicsMicroporousMicroporous coatingsNarrow gapPlate wettability
All Science Classification Codes (ASJC)
Condensed Matter PhysicsMechanical EngineeringFluid Flow and Transfer Processes
Abstract
An experimental study on boiling heat transfer with distilled water and a copper high-temperature thermally-conductive microporous coating (Cu-HTCMC) is performed in a narrow gap of 0.64, 1, 2, 3, and 5 mm thickness with hydrophilic and hydrophobic cover plates having apparent contact angles of 11°, 70°, and 150°. The parahydrophobic nature of the microporous copper coating and the interconnected channels within the coating allow the heating surface to stay wet and the boiling heat transfer performance to significantly exceed that of an uncoated copper surface. A hydrophobic cover plate causes stratified flow in the narrow gap, while a hydrophilic cover plate causes a laterally growing bubble in the gap. Regardless of the cover plate wettability, the wall superheat follows the unconfined case without any deterioration in the narrow gap up to the dryout heat flux due to the Cu-HTCMC on the boiling surface. Furthermore, minimal reduction in the critical heat flux is observed in narrow gap boiling with a hydrophobic cover plate, but significant reduction is observed with hydrophilic cover plates. The wettability effect diminishes as the gap size ≤ 1 mm since the vapor fills the narrow gap. For such gap sizes, the heat transfer coefficient enhancement is observed at low heat flux, followed by a sudden drop when vapor fills the gap and the surface struggles to stay wet.
Language
eng
URI
https://aurora.ajou.ac.kr/handle/2018.oak/38168
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=105000156923&origin=inward
DOI
https://doi.org/10.1016/j.ijheatmasstransfer.2025.126956
Journal URL
https://www.sciencedirect.com/science/journal/00179310
Type
Article
Funding
This work was supported by the International Cooperative R&D Program of the Korea Institute of Energy Technology Evaluation and Planning (KETEP), a grant funded by the Ministry of Trade, Industry & Energy, Korea. (Grant No. RS-2024\u201300436521).
Show full item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Lee, Jungho  Image
Lee, Jungho 이정호
Department of Mechanical Engineering
Read More

Total Views & Downloads

File Download

  • There are no files associated with this item.