The Ergonomic Design of Wearable Robot Based on the Shoulder Kinematic Analysis by Walking Speed
Citations

SCOPUS

0

Citation Export

DC Field Value Language
dc.contributor.authorMo, Seung Min-
dc.contributor.authorHwang, Jaejin-
dc.contributor.authorKim, Jae Ho-
dc.contributor.authorJung, Myung Chul-
dc.date.issued2020-01-01-
dc.identifier.urihttps://aurora.ajou.ac.kr/handle/2018.oak/36556-
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85068239848&origin=inward-
dc.description.abstractThe purpose of this study was to suggest the design of wearable robots based on the shoulder kinematics including the range of motion, angular velocity, and angular acceleration during walking. A treadmill system was used to measure the kinematics data of the shoulder joint during different walking speed. The independent variables of this study were walking speed. Walking speed was set as four levels including 3.6, 5.4, 7.2, and preferred walking speed (PWS) km/h. The subject walked according to the randomized walking speed during 90Â s on the treadmill. Twenty gait cycles of motion capture data from each experimental condition of each subject were extracted. Data was analyzed by one-way repeated measures analysis of variance. There were significant differences of minimum joint angle, mean of ROM, maximum joint angular velocity, minimum joint angular velocity, maximum joint angular acceleration and minimum joint angular acceleration. There was no significant difference of maximum joint angle. The kinematics data of ROM, angular velocity, and angular acceleration revealed an increasing trend up to walking speed of 7.2Â km/h. It indicates that the arm swinging was sufficiently performed to maintain the walking stability. The maximum angular acceleration increased as the walking speed increased, which meant the instantaneous velocity of the shoulder joint increased. It indicated that the load of the shoulder joint increased with the increase of the walking speed. Hence, this study suggests that the ergonomic threshold for walking speed of the wearable robot could be limited to 5.4Â km/h.-
dc.description.sponsorshipAcknowledgments. This study was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (NRF-2017R1D1A3B03035407).-
dc.language.isoeng-
dc.publisherSpringer Verlag-
dc.subject.meshAngular acceleration-
dc.subject.meshExperimental conditions-
dc.subject.meshIndependent variables-
dc.subject.meshJoint angular velocity-
dc.subject.meshKinematic Analysis-
dc.subject.meshMotion capture data-
dc.subject.meshWalking speed-
dc.subject.meshWearable robots-
dc.titleThe Ergonomic Design of Wearable Robot Based on the Shoulder Kinematic Analysis by Walking Speed-
dc.typeConference-
dc.citation.conferenceDate2019.7.24. ~ 2019.7.28.-
dc.citation.conferenceNameAHFE International Conference on Human Factors and Wearable Technologies, 2019 and the AHFE International Conference on Game Design and Virtual Environments, 2019-
dc.citation.editionAdvances in Human Factors in Wearable Technologies and Game Design - Proceedings of the AHFE International Conference on Human Factors and Wearable Technologies, and the AHFE International Conference on Game Design and Virtual Environments, 2019-
dc.citation.endPage69-
dc.citation.startPage63-
dc.citation.titleAdvances in Intelligent Systems and Computing-
dc.citation.volume973-
dc.identifier.bibliographicCitationAdvances in Intelligent Systems and Computing, Vol.973, pp.63-69-
dc.identifier.doi10.1007/978-3-030-20476-1_8-
dc.identifier.scopusid2-s2.0-85068239848-
dc.identifier.urlhttp://www.springer.com/series/11156-
dc.subject.keywordHuman-robot interaction-
dc.subject.keywordKinematics-
dc.subject.keywordShoulder-
dc.subject.keywordWalking speed-
dc.subject.keywordWearable robot-
dc.type.otherConference Paper-
dc.description.isoafalse-
dc.subject.subareaControl and Systems Engineering-
dc.subject.subareaComputer Science (all)-
Show simple item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Jung, Myung-Chul Image
Jung, Myung-Chul정명철
Department of Industrial Engineering
Read More

Total Views & Downloads

File Download

  • There are no files associated with this item.