Ajou University repository

Bolt-free post-tensioned connection for steel-framed modular buildings and design for optimal preloadingoa mark
Citations

SCOPUS

8

Citation Export

Publication Year
2024-07-01
Publisher
Elsevier Ltd
Citation
Journal of Constructional Steel Research, Vol.218
Keyword
DesignInter-module connectionModular steel buildingPost-tensioned connectionPrefabricated construction
Mesh Keyword
Gap openingInter-moduleInter-module connectionModular buildingsModular steel buildingModularsPost tensionedPost-tensioned connectionPre loadsSteel buildings
All Science Classification Codes (ASJC)
Civil and Structural EngineeringBuilding and ConstructionMechanics of MaterialsMetals and Alloys
Abstract
This paper introduces a novel bolt-free preloaded column-to-column connection, termed the ‘AJ connection’, for steel-framed modular buildings. The AJ connection is classified as a post-tensioned inter-module connection, and modules are connected vertically by preload, using specially designed couplers and high-tensile steel rod bolts (SRB) within the columns. The AJ connection enables easy assembly and disassembly processes of modular buildings by inducing preload on top of the modules using a torque or impact wrench, thus improving construction speed and reusability. The paper also establishes a design method, not previously attempted in the literature, to determine the minimum necessary preload for the connection. The primary aim of this method is to design against potential failures by gap-opening and slip between modules, commonly associated with existing post-tensioned inter-module connections. The effectiveness of the suggested method is verified through numerical simulations using FE joint models that have been calibrated against monotonic loading test results. Furthermore, the study investigates the adverse effects of gap-opening and slip at the connection on the performance of the beam-to-column joint and the SRBs within the columns. The findings indicate that (i) minimising the difference between the flexural stiffness of the floor and ceiling beams reduces the impact of gap-opening, and (ii) the rotation of the coupler caused by plate bearing due to slip prior to gap-opening affects the induced preload in the SRBs and leads to premature gap-opening at the connection.
ISSN
0143-974X
Language
eng
URI
https://dspace.ajou.ac.kr/dev/handle/2018.oak/34171
DOI
https://doi.org/10.1016/j.jcsr.2024.108703
Fulltext

Type
Article
Funding
This research was supported by the Australian Government through the Australian Research Council - Centre for Advanced Manufacturing of Prefabricated Housing (CAMPH) Project and from the National Research Foundation of Korea (Grant number: 2022R1F1A1075815 ).This research was supported by the Australian Government through the Australian Research Council- Industrial Transformation Training Centre for Advanced Manufacturing of Prefabricated Housing (CAMP.H) Project IC150100023 and from the National Research Foundation of Korea (Grant number: 2022R1F1A1075815).
Show full item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

CHO, BONG HO Image
CHO, BONG HO조봉호
Department of Architecture
Read More

Total Views & Downloads

File Download

  • There are no files associated with this item.