Ajou University repository

직류 계통망에서 Dual-active-bridge 컨버터의 독립운전기법
  • 허윤재
Citations

SCOPUS

0

Citation Export

DC Field Value Language
dc.contributor.advisor이교범-
dc.contributor.author허윤재-
dc.date.issued2024-08-
dc.identifier.other34154-
dc.identifier.urihttps://aurora.ajou.ac.kr/handle/2018.oak/39412-
dc.description학위논문(석사)--전자공학과,2024. 8-
dc.description.abstractThis paper proposes an islanded operation technique using DC-DC converters. When the AC grid blackouts within the DC grid, the islanded operation technique becomes essential. Voltage control is necessary according to the islanded operation technique of DC-DC converters. This paper shows soft-start and voltage control using Dual-active-bridge converters for stable operation in the DC grid. The validity of the proposed islanded operation technique is demonstrated by the experimental results.-
dc.description.tableofcontents제 1 장 서론 1_x000D_ <br>제 2 장 직류 계통망의 구성 . 3_x000D_ <br>2.1 직류 계통망의 개요 3_x000D_ <br>2.2 직류 계통망의 개발의 필요성 7_x000D_ <br>2.3 직류 계통망에서 DC-DC 컨버터의 활용 9_x000D_ <br>2.4 직류 계통망에서 Dual-active-bridge 컨버터의 적용 . 12_x000D_ <br>제 3 장 Dual-active-bridge 컨버터 13_x000D_ <br>3.1 Dual-active-bridge 컨버터의 특징 13_x000D_ <br>3.2 Dual-active-bridge 컨버터의 동작 특성 16_x000D_ <br>제 4 장 독립운전을 위한 전압제어 방법 . 21_x000D_ <br>4.1 전압 제어 방법 21_x000D_ <br>4.2 소프트 스타트 알고리즘 23_x000D_ <br>제 5 장 실험 결과 24_x000D_ <br>5.1 실험 결과 26_x000D_ <br>제 6 장 결론 29_x000D_ <br>참고문헌 30-
dc.language.isokor-
dc.publisherThe Graduate School, Ajou University-
dc.rights아주대학교 논문은 저작권에 의해 보호받습니다.-
dc.title직류 계통망에서 Dual-active-bridge 컨버터의 독립운전기법-
dc.typeThesis-
dc.contributor.affiliation아주대학교 대학원-
dc.contributor.alternativeNameHeo Yoon Jae-
dc.contributor.department일반대학원 전자공학과-
dc.date.awarded2024-08-
dc.description.degreeMaster-
dc.identifier.urlhttps://dcoll.ajou.ac.kr/dcollection/common/orgView/000000034154-
dc.subject.keywordDual-active-bridge-
dc.subject.keyword직류 계통망-
dc.description.alternativeAbstractThis paper proposes an islanded operation technique using DC-DC converters. When the AC grid blackouts within the DC grid, the islanded operation technique becomes essential. Voltage control is necessary according to the islanded operation technique of DC-DC converters. This paper shows soft-start and voltage control using Dual-active-bridge converters for stable operation in the DC grid. The validity of the proposed islanded operation technique is demonstrated by the experimental results.-
Show simple item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Total Views & Downloads

File Download

  • There are no files associated with this item.