Ajou University repository

A 0.052 mm2, <0.4% THD, Sinusoidal Current Generator for Bio-Impedance Measurement Using a Recursive Digital Oscillator and Current-Domain FIR Filter
Citations

SCOPUS

32

Citation Export

DC Field Value Language
dc.contributor.authorHong, Seok Ki-
dc.contributor.authorJee, Dong Woo-
dc.date.issued2019-06-01-
dc.identifier.issn1558-3791-
dc.identifier.urihttps://aurora.ajou.ac.kr/handle/2018.oak/30376-
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85053619343&origin=inward-
dc.description.abstractThis brief presents a low-power, low-area and low total harmonic distortion (THD) sinusoidal current stimulator circuit for bio-impedance measurement. Proposed current generator includes recursive digital oscillator for sine wave generation and delta-sigma modulated 1 bit current source with embedded finite impulse response filter for high resolution digital-to-current conversion. The proposed circuit implemented in 0.18-μ m CMOS process occupies 0.052 mm2, and consumes 55.6 μ W for 20 kHz, 40 μ Ap-p, 0.17% THD sine current generation.-
dc.description.sponsorshipManuscript received May 2, 2018; revised August 23, 2018; accepted September 12, 2018. Date of publication September 18, 2018; date of current version May 28, 2019. This work was supported in part by MSIT, South Korea, through the ITRC Support Program supervised by the IITP under Grant IITP-2018-2016-0-00309-002, and in part by NRF of Korea under Grant NRF-2018R1C1B6003216. This brief was recommended by Associate Editor L. A. B. G. Oliveira. (Corresponding author: Dong-Woo Jee.) The authors are with the Department of Electrical and Computer Engineering, Ajou University, Suwon 16944, South Korea (e-mail: dwjee@ajou.ac.kr).-
dc.language.isoeng-
dc.publisherInstitute of Electrical and Electronics Engineers Inc.-
dc.subject.meshBio-impedance-
dc.subject.meshDelta sigma modulator-
dc.subject.meshDigital oscillators-
dc.subject.meshLow area-
dc.subject.meshLow Power-
dc.subject.meshSine wave generator-
dc.subject.meshTotal harmonic distortion (THD)-
dc.titleA 0.052 mm2, &lt;0.4% THD, Sinusoidal Current Generator for Bio-Impedance Measurement Using a Recursive Digital Oscillator and Current-Domain FIR Filter-
dc.typeArticle-
dc.citation.endPage898-
dc.citation.number6-
dc.citation.startPage894-
dc.citation.titleIEEE Transactions on Circuits and Systems II: Express Briefs-
dc.citation.volume66-
dc.identifier.bibliographicCitationIEEE Transactions on Circuits and Systems II: Express Briefs, Vol.66 No.6, pp.894-898-
dc.identifier.doi10.1109/tcsii.2018.2870833-
dc.identifier.scopusid2-s2.0-85053619343-
dc.identifier.urlhttp://www.ieee-cas.org-
dc.subject.keywordbio-impedance-
dc.subject.keyworddelta-sigma modulator-
dc.subject.keywordFIR filter-
dc.subject.keywordlow area-
dc.subject.keywordlow power-
dc.subject.keywordrecursive digital oscillator-
dc.subject.keywordSine wave generator-
dc.subject.keywordtotal harmonic distortion-
dc.type.otherArticle-
dc.identifier.pissn1549-7747-
dc.description.isoafalse-
dc.subject.subareaElectrical and Electronic Engineering-
Show simple item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

 Jee, Dong Woo Image
Jee, Dong Woo지동우
Department of Electrical and Computer Engineering
Read More

Total Views & Downloads

File Download

  • There are no files associated with this item.