Ajou University repository

Impact force and occurrence condition of geyser boiling in two-phase closed thermosyphon
Citations

SCOPUS

1

Citation Export

Publication Year
2024-12-01
Publisher
Elsevier Ltd
Citation
International Communications in Heat and Mass Transfer, Vol.159
Keyword
Filling ratioGeyser boiling phenomena (GBP)Heat fluxImpact forceTwo-phase closed thermosyphon (TPCT)
Mesh Keyword
Average forceFilling ratioForce conditionsGeyse boiling phenomenonImpact forceLiquid layerOccurrence conditionsTwo-phase closed thermosiphonTwo-phase closed thermosyphonUnstable behavior
All Science Classification Codes (ASJC)
Atomic and Molecular Physics, and OpticsChemical Engineering (all)Condensed Matter Physics
Abstract
The Geyser boiling phenomenon (GBP) is unstable behavior inside a two-phase closed thermosyphon (TPCT). The mechanism of GBP occurrence is still not clearly understood. Therefore, understanding GBP is not just an academic pursuit but is essential for designing the TPCT. Based on the visualization, the GBP was defined, and a novel experiment with synchronized measurement among temperature, pressure, and force analyzed the mechanism of GBP. Experiments were taken to understand GBP by varying filling ratios (50 %, 75 %, and 100 %) of working fluid and heat fluxes. The results showed that a sufficient liquid layer at the top of the bubble is required for GBP to occur and that the bubble growth rate affects the thickness of the liquid layer. When GBP occurred, the average force was at least 0.5 N, but in some cases, an average force of 1 N or more appeared under the condition that GBP did not occur. When the frequency of the force was high, even a small average force could make a significant cumulative force. This study provides valuable information for numerical analysis based on the quantitative forces measured by the load cell, opening a new perspective on the safety and reliability of TPCTs.
ISSN
0735-1933
Language
eng
URI
https://dspace.ajou.ac.kr/dev/handle/2018.oak/34543
DOI
https://doi.org/10.1016/j.icheatmasstransfer.2024.108262
Fulltext

Type
Article
Funding
This work was supported by the Innovative Energy Efficiency R&D Program of the Korea Institute of Energy Technology Evaluation and Planning (KETEP) grant funded by the Ministry of Trade, Industry & Energy, Korea . (Grant No. 20212020800270 ), and a National Research Foundation of Korea (NRF) grant funded by the Ministry of Science and ICT, Korea (No. NRF-2020R1A2C3008689 ).
Show full item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Lee, Jungho  Image
Lee, Jungho 이정호
Department of Mechanical Engineering
Read More

Total Views & Downloads

File Download

  • There are no files associated with this item.