Ajou University repository

Phase current control to reduce unbalanced outputs in paralleled inverters
Citations

SCOPUS

0

Citation Export

DC Field Value Language
dc.contributor.authorLee, Bong Ki-
dc.contributor.authorLee, Heon Su-
dc.contributor.authorLee, Kyo Beum-
dc.date.issued2024-10-01-
dc.identifier.urihttps://dspace.ajou.ac.kr/dev/handle/2018.oak/34381-
dc.description.abstractWhen paralleled inverters operate an electric motor, a circulating current is typically generated due to a device-switching timing error. To mitigate this error, an AC reactor is installed at the output of the inverters to reduce the circulating current. However, unbalanced output currents (UOCs) are produced due to the difference between the resistance and inductance in the AC reactor. When there is a difference in the output currents of the inverters, a single inverter outputs excessive current. As a result, the motor cannot be controlled to its maximum power. In this study, mathematical modeling is performed and the causes for the generation of UOCs in parallel connected electric motor drive systems are analyzed. Furthermore, the unbalanced load is minimized by controlling the current output based on the output status of the inverters in the control algorithms of a motor. The proposed control method is experimentally verified by implementing a system that connects three inverters in parallel.-
dc.description.sponsorshipThis work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korean government (MSIT), the Korea Institute of Energy Technology Evaluation and Planning (KETEP), and the Ministry of Trade, Industry & Energy (MOTIE) of the Republic of Korea (No. RS-2024-00333208, No. 20225500000110).-
dc.language.isoeng-
dc.publisherSpringer-
dc.subject.meshCirculating current-
dc.subject.meshMotor control-
dc.subject.meshOutput current-
dc.subject.meshParalleled inverters-
dc.subject.meshParalleled operation-
dc.subject.meshPhase current control-
dc.subject.meshPhase currents-
dc.subject.meshScalar motor control-
dc.subject.meshTiming errors-
dc.subject.meshUnbalanced output current-
dc.titlePhase current control to reduce unbalanced outputs in paralleled inverters-
dc.typeArticle-
dc.citation.endPage1638-
dc.citation.startPage1628-
dc.citation.titleJournal of Power Electronics-
dc.citation.volume24-
dc.identifier.bibliographicCitationJournal of Power Electronics, Vol.24, pp.1628-1638-
dc.identifier.doi10.1007/s43236-024-00885-3-
dc.identifier.scopusid2-s2.0-85200908286-
dc.identifier.urlhttps://www.springer.com/journal/43236-
dc.subject.keywordParalleled operation-
dc.subject.keywordPhase current control-
dc.subject.keywordScalar motor control-
dc.subject.keywordUnbalanced output currents-
dc.description.isoafalse-
dc.subject.subareaControl and Systems Engineering-
dc.subject.subareaElectrical and Electronic Engineering-
Show simple item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

 Lee, Kyo-Beum Image
Lee, Kyo-Beum이교범
Department of Electrical and Computer Engineering
Read More

Total Views & Downloads

File Download

  • There are no files associated with this item.