Ajou University repository

Transient shuttle for a widespread neural probe with minimal perturbationoa mark
  • Roh, Yeonwook ;
  • Kim, Hyeongseok ;
  • Kim, Eun A. ;
  • Ji, Kyungbin ;
  • Kang, Minji ;
  • Gong, Dohyeon ;
  • Im, Sunghoon ;
  • Hong, Insic ;
  • Park, Jieun ;
  • Park, Soo Jung ;
  • Bae, Yiseul ;
  • Park, Jae Il ;
  • Koh, Je Sung ;
  • Han, Seungyong ;
  • Lee, Eun Jeong ;
  • Kang, Daeshik
Citations

SCOPUS

1

Citation Export

DC Field Value Language
dc.contributor.authorRoh, Yeonwook-
dc.contributor.authorKim, Hyeongseok-
dc.contributor.authorKim, Eun A.-
dc.contributor.authorJi, Kyungbin-
dc.contributor.authorKang, Minji-
dc.contributor.authorGong, Dohyeon-
dc.contributor.authorIm, Sunghoon-
dc.contributor.authorHong, Insic-
dc.contributor.authorPark, Jieun-
dc.contributor.authorPark, Soo Jung-
dc.contributor.authorBae, Yiseul-
dc.contributor.authorPark, Jae Il-
dc.contributor.authorKoh, Je Sung-
dc.contributor.authorHan, Seungyong-
dc.contributor.authorLee, Eun Jeong-
dc.contributor.authorKang, Daeshik-
dc.date.issued2024-12-01-
dc.identifier.issn2397-4621-
dc.identifier.urihttps://dspace.ajou.ac.kr/dev/handle/2018.oak/34317-
dc.description.abstractBioelectronic implants in the deep brain provide the opportunity to monitor deep brain activity with potential applications in disease diagnostics and treatment. However, mechanical mismatch between a probe and brain tissue can cause surgical trauma in the brain and limit chronic probe-based monitoring, leading to performance degradation. Here, we report a transient shuttle-based probe consisting of a PVA and a mesh-type probe. A rigid shuttle based on PVA implants an ultrathin mesh probe in the target deep brain without a tangle, while creating both a sharp edge for facile penetration into the brain and an anti-friction layer between the probe and brain tissue through dissolving its surface. The capability to shuttle dissolved materials can exclude the retracted process of the shuttle in the brain. Complete dissolution of the shuttle provides a dramatic decrease (~1078-fold) in the stiffness of the probe, which can therefore chronically monitor a wide area of the brain. These results indicate the ability to use a simplistic design for implantation of wide and deep brain probes while preventing unnecessary damage to the brain and probe degradation during long-term use.-
dc.description.sponsorshipThis work is supported by funding from the NRF of Korea (grant no. 2022R1C1C1005741, 2022R1A2C2093100, RS-2023-00217595, and RS-2023-00271830). We obtained new faculty research funding from Ajou University and funding from Ajou University. This work was supported by the Korea Environment Industry & Technology Institute (KEITI) through the Digital Infrastructure Building Project for Monitoring, Surveying, and Evaluating the Environmental Health Program, funded by the Korea Ministry of Environment (MOE) (2021003330009). We thank Prof. Huyk-Wan Ko at Yonsei Univeristy for generously providing the GFAP antibodies.-
dc.language.isoeng-
dc.publisherNature Research-
dc.titleTransient shuttle for a widespread neural probe with minimal perturbation-
dc.typeArticle-
dc.citation.titlenpj Flexible Electronics-
dc.citation.volume8-
dc.identifier.bibliographicCitationnpj Flexible Electronics, Vol.8-
dc.identifier.doi10.1038/s41528-024-00328-w-
dc.identifier.scopusid2-s2.0-85198327270-
dc.identifier.urlhttps://www.nature.com/npjflexelectron/-
dc.description.isoatrue-
dc.subject.subareaMaterials Science (all)-
dc.subject.subareaElectrical and Electronic Engineering-
Show simple item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Koh, Jesung  Image
Koh, Jesung 고제성
Department of Mechanical Engineering
Read More

Total Views & Downloads

File Download

  • There are no files associated with this item.