Ajou University repository

Effect of inner diameter on the confinement of two-phase closed thermosyphon
Citations

SCOPUS

10

Citation Export

DC Field Value Language
dc.contributor.authorKang, Sukkyung-
dc.contributor.authorSeo, Jin Hyeuk-
dc.contributor.authorLee, Jungho-
dc.date.issued2023-10-01-
dc.identifier.issn0735-1933-
dc.identifier.urihttps://dspace.ajou.ac.kr/dev/handle/2018.oak/33691-
dc.description.abstractA two-phase closed thermosyphon (TPCT) is a heat transfer device that effectively transfers heat through the phase change of a working fluid. While the working fluid circulates smoothly in a nominal TPCT, compact TCPT has a greater shear force effect between the upward vapor flow and the falling liquid. The inner diameter and type of working fluid significantly affect the confinement effect, but the effects of the inner diameter on the confinement remain unclear. In the case of Co > 0.5, the TPCT was fully confined, so the heat was dominantly transferred by axial conduction through the confined bubbles and liquid slugs. For Co < 0.5, the working fluid circulated smoothly, and the heat was mainlytransferred by latent heat. In the unconfined case, the heat transfer coefficient at the evaporator slightly increased at high Co owing to the mixing effect within the liquid pool. In the condenser, the cold surface was covered with liquid at high Co values owing to the re-rising of falling liquid by the high shear rate. As a result, the overall thermal resistance of the TPCT increased at high Co values due to the significant degradation in the thermal performance of the condenser.-
dc.description.sponsorshipThis work was supported by the Innovative Energy Efficiency R&D Program of the Korea Institute of Energy Technology Evaluation and Planning (KETEP) grant funded by the Ministry of Trade, Industry & Energy , Korea. (Grant No. 20212020800270 ), and a National Research Foundation of Korea (NRF) grant funded by the Ministry of Science and ICT , Korea (No. NRF-2020R1A2C3008689 ).-
dc.language.isoeng-
dc.publisherElsevier Ltd-
dc.subject.meshAxial conduction-
dc.subject.meshConfinement effects-
dc.subject.meshForce effects-
dc.subject.meshHeat transfer device-
dc.subject.meshInner diameters-
dc.subject.meshPhase Change-
dc.subject.meshShear force-
dc.subject.meshTwo-phase closed thermosyphon-
dc.subject.meshVapor flows-
dc.subject.meshWorking fluid-
dc.titleEffect of inner diameter on the confinement of two-phase closed thermosyphon-
dc.typeArticle-
dc.citation.titleInternational Communications in Heat and Mass Transfer-
dc.citation.volume147-
dc.identifier.bibliographicCitationInternational Communications in Heat and Mass Transfer, Vol.147-
dc.identifier.doi10.1016/j.icheatmasstransfer.2023.106997-
dc.identifier.scopusid2-s2.0-85172218280-
dc.identifier.urlhttps://www.journals.elsevier.com/international-communications-in-heat-and-mass-transfer-
dc.subject.keywordConfinement effect-
dc.subject.keywordInner diameter-
dc.subject.keywordTwo-phase closed thermosyphon-
dc.description.isoafalse-
dc.subject.subareaAtomic and Molecular Physics, and Optics-
dc.subject.subareaChemical Engineering (all)-
dc.subject.subareaCondensed Matter Physics-
Show simple item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Lee, Jungho  Image
Lee, Jungho 이정호
Department of Mechanical Engineering
Read More

Total Views & Downloads

File Download

  • There are no files associated with this item.