Ajou University repository

Mechanical effects of surgical variations in the femoral neck system on Pauwels type III femoral neck fractureoa mark
  • Jung, C. H. ;
  • Cha, Y. ;
  • Yoon, H. S. ;
  • Park, C. H. ;
  • Yoo, J. I. ;
  • Kim, J. T. ;
  • Jeon, Y.
Citations

SCOPUS

38

Citation Export

DC Field Value Language
dc.contributor.authorJung, C. H.-
dc.contributor.authorCha, Y.-
dc.contributor.authorYoon, H. S.-
dc.contributor.authorPark, C. H.-
dc.contributor.authorYoo, J. I.-
dc.contributor.authorKim, J. T.-
dc.contributor.authorJeon, Y.-
dc.date.issued2022-02-01-
dc.identifier.issn2046-3758-
dc.identifier.urihttps://dspace.ajou.ac.kr/dev/handle/2018.oak/32554-
dc.description.abstractAims In this study, we aimed to explore surgical variations in the Femoral Neck System (FNS) used for stable fixation of Pauwels type III femoral neck fractures. Methods Finite element models were established with surgical variations in the distance between the implant tip and subchondral bone, the gap between the plate and lateral femoral cortex, and inferior implant positioning. The models were subjected to physiological load. Results Under a load of single-leg stance, Pauwels type III femoral neck fractures fixed with 10 mm shorter bolts revealed a 7% increase of the interfragmentary gap. The interfragmentary sliding, compressive, and shear stress remained similar to models with bolt tips positioned close to the subchondral bone. Inferior positioning of FNS provided a similar interfragmentary distance, but with 6% increase of the interfragmentary sliding distance compared to central positioning of bolts. Inferior positioning resulted in a one-third increase in interfragmentary compressive and shear stress. A 5 mm gap placed between the diaphysis and plate provided stability comparable to standard fixation, with a 7% decrease of interfragmentary gap and sliding distance, but similar compressive and shear stress. Conclusion Finite element analysis with FNS on Pauwels type III femoral neck fractures revealed that placement of the bolt tip close to subchondral bone provides increased stability. Inferior positioning of FNS bolt increased interfragmentary sliding distance, compressive, and shear stress. The comparable stability of the fixation model with the standard model suggests that a 5 mm gap placed between the plate and diaphysis could viably adjust the depth of the bolt.-
dc.language.isoeng-
dc.publisherBritish Editorial Society of Bone and Joint Surgery-
dc.titleMechanical effects of surgical variations in the femoral neck system on Pauwels type III femoral neck fracture-
dc.typeArticle-
dc.citation.endPage111-
dc.citation.startPage102-
dc.citation.titleBone and Joint Research-
dc.citation.volume11-
dc.identifier.bibliographicCitationBone and Joint Research, Vol.11, pp.102-111-
dc.identifier.doi10.1302/2046-3758.112.bjr-2021-0282.r1-
dc.identifier.scopusid2-s2.0-85124996177-
dc.identifier.urlhttps://online.boneandjoint.org.uk/doi/full/10.1302/2046-3758.112.BJR-2021-0282.R1-
dc.subject.keywordFemoral neck fracture-
dc.subject.keywordFemoral neck system-
dc.subject.keywordFinite element analysis-
dc.description.isoatrue-
dc.subject.subareaSurgery-
dc.subject.subareaOrthopedics and Sports Medicine-
Show simple item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Jeon, Yongho  Image
Jeon, Yongho 전용호
Department of Mechanical Engineering
Read More

Total Views & Downloads

File Download

  • There are no files associated with this item.