This paper proposes optimal conduction angle for noise reduction in xEV BLDC wiper motors. Fuzzy logic simulation is performed to review the noise influences by conduction angle. After confirming that the current and torque ripple change according to the parameter change, and the optimized control method and parameters from the simulation to the controller is reflected. A test is conducted to reduce noise in a specific frequency range. Noise influences are verified through Fast Fourier Transform analysis on current wave forms and noise test results.
This research was supported by Korea Electric Power Corporation, Korea Institute of Energy Technology Evaluation and Planning, and the Ministry of Trade, Industry & Energy (Grant number : R21XO01-11 and Grant number : 20194030202370)