Wash-free operation of smartphone-integrated optical immunosensor using retroreflective microparticles
  • Kim, Ka Ram ;
  • Lee, Kyung Won ;
  • Chun, Hyeong Jin ;
  • Lee, Danbi ;
  • Kim, Jae Ho ;
  • Yoon, Hyun C.
Citations

SCOPUS

12

Citation Export

DC Field Value Language
dc.contributor.authorKim, Ka Ram-
dc.contributor.authorLee, Kyung Won-
dc.contributor.authorChun, Hyeong Jin-
dc.contributor.authorLee, Danbi-
dc.contributor.authorKim, Jae Ho-
dc.contributor.authorYoon, Hyun C.-
dc.date.issued2022-01-15-
dc.identifier.urihttps://dspace.ajou.ac.kr/dev/handle/2018.oak/32336-
dc.description.abstractHerein, we introduce a smartphone-integrated immunosensor based on non-spectroscopic optical detection. Sedimentation of the retroreflector and gentle inversion of the microfluidic chip was chosen as biosensing principles to ensure minimal human involvement. To realize this, wash-free immunosensing was implemented on a polymeric microfluidic chip device fabricated for light signal penetration in retroreflection signal acquisition. Applying a transparent chip and passive modulation of retroreflectors enabled the minimization of human error during sensing. In addition, a retroreflection-detectable optical gadget was constructed for integration with the commercial smartphone. The gadget had an optical chamber that induced retroreflection by integration with a smartphone. When the micro-sized reflector, named the retroreflective Janus microparticle, reacted on the sensing surface, the incident light was retroreflected towards the image sensor and quantified by a smartphone-installed Android application package. The developed application package features include time-lapse image capture performed by manipulating LED flash and camera modules, and quantification of retroreflected signal counts by image processing of time-lapse images. With this platform, the user could independently commence optical signal processing without a complicated optical setup and running software on a PC, and sensitive and reproducible immunosensing results could be obtained. The applicability test for creatine kinase-myocardial band detection from the buffer to serum was conducted and presented a calibration curve of 0–1000 ng/mL within 1 h. With the developed system, we believe that the applicability of the platform in bioanalytical detection can be expanded.-
dc.description.sponsorshipThis work was supported by the Creative Materials Discovery Program (NRF- 2019M3D1A1078943 ), the Priority Research Centers Program (NRF- 2019R1A6A1A11051471 ), and the SGER Program (NRF- 2018R1D1A1A02085354 ) funded by the National Research Foundation of Korea . HCY also acknowledges the support from the Samsung Research Funding Centre of Samsung Electronics .-
dc.description.sponsorshipThis work was supported by the Creative Materials Discovery Program (NRF-2019M3D1A1078943), the Priority Research Centers Program (NRF-2019R1A6A1A11051471), and the SGER Program (NRF-2018R1D1A1A02085354) funded by the National Research Foundation of Korea. HCY also acknowledges the support from the Samsung Research Funding Centre of Samsung Electronics.-
dc.language.isoeng-
dc.publisherElsevier Ltd-
dc.subject.meshCreatine kinase-
dc.subject.meshCreatine kinase-MB-
dc.subject.meshImmunosensing-
dc.subject.meshMicro particles-
dc.subject.meshMicrofluidic-chips-
dc.subject.meshOptical bio-sensing-
dc.subject.meshRetro reflection-
dc.subject.meshRetro-reflectors-
dc.subject.meshSmart phones-
dc.subject.meshSmartphone-based biosensor-
dc.subject.meshBiosensing Techniques-
dc.subject.meshHumans-
dc.subject.meshImmunoassay-
dc.subject.meshLab-On-A-Chip Devices-
dc.subject.meshMicrofluidics-
dc.subject.meshSmartphone-
dc.titleWash-free operation of smartphone-integrated optical immunosensor using retroreflective microparticles-
dc.typeArticle-
dc.citation.titleBiosensors and Bioelectronics-
dc.citation.volume196-
dc.identifier.bibliographicCitationBiosensors and Bioelectronics, Vol.196-
dc.identifier.doi10.1016/j.bios.2021.113722-
dc.identifier.pmid34700265-
dc.identifier.scopusid2-s2.0-85117695145-
dc.identifier.urlwww.elsevier.com/locate/bios-
dc.subject.keywordCreatine kinase-MB-
dc.subject.keywordImmunosensing-
dc.subject.keywordOptical biosensing-
dc.subject.keywordRetroreflection-
dc.subject.keywordSmartphone-based biosensor-
dc.description.isoafalse-
dc.subject.subareaBiotechnology-
dc.subject.subareaBiophysics-
dc.subject.subareaBiomedical Engineering-
dc.subject.subareaElectrochemistry-
Show simple item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Yoon, Hyun Chul Image
Yoon, Hyun Chul윤현철
College of Bio-convergence Engineering
Read More

Total Views & Downloads

File Download

  • There are no files associated with this item.