Analysis of the calculation method for the thermal transmittance of double windows considering the thermal properties of the air cavityoa mark
  • Bae, Minjung ;
  • Lee, Youngjun ;
  • Choi, Gyeongseok ;
  • Kim, Sunsook ;
  • Kang, Jaesik
Citations

SCOPUS

1

Citation Export

DC Field Value Language
dc.contributor.authorBae, Minjung-
dc.contributor.authorLee, Youngjun-
dc.contributor.authorChoi, Gyeongseok-
dc.contributor.authorKim, Sunsook-
dc.contributor.authorKang, Jaesik-
dc.date.issued2020-12-02-
dc.identifier.issn2071-1050-
dc.identifier.urihttps://dspace.ajou.ac.kr/dev/handle/2018.oak/31718-
dc.description.abstractThe calculation method for the thermal transmittance (U-value) of double windows as specified by the Korean government (ISO 15099) is often inappropriate. To develop a more suitable calculation method, the thermal properties of the air cavity between the internal and external windows should be considered. Herein, seven cases of double windows were set up. The air cavities were designed in accordance with international standards and computational fluid dynamics (CFD) and used for the calculation of the U-values of the double windows according to ISO 15099 and 10077. All the calculated U-values were compared with experimentally obtained values. In accordance with the ISO 10077-1 method, the thermal resistance of the air cavity calculated using CFD could produce double window U-values that are similar to the experimentally obtained values. In most cases, the difference between the theoretical and experimental U-values was 5% and less than 0.14 W· m−2· K−1, implying that the U-values calculated using CFD and the ISO 10077-1 method are approximately equal to the experimentally obtained U-values. Korean regulations do not include ISO 10077-1 for double-window assessment. However, these criteria can provide a solution in improving the accuracy of the calculation of the overall thermal transmittance of double windows.-
dc.description.sponsorshipFunding: This research was supported by a grant (20RERP-C146906-03) from the Residential Environment Research Program funded by the Ministry of Land, Infrastructure, and Transport of the Korean government.-
dc.language.isoeng-
dc.publisherMDPI-
dc.titleAnalysis of the calculation method for the thermal transmittance of double windows considering the thermal properties of the air cavity-
dc.typeArticle-
dc.citation.endPage11-
dc.citation.startPage1-
dc.citation.titleSustainability (Switzerland)-
dc.citation.volume12-
dc.identifier.bibliographicCitationSustainability (Switzerland), Vol.12, pp.1-11-
dc.identifier.doi10.3390/su122410439-
dc.identifier.scopusid2-s2.0-85097772027-
dc.identifier.urlhttps://www.mdpi.com/2071-1050/12/24/10439/pdf-
dc.subject.keywordDouble windows-
dc.subject.keywordEnergy labeling program for windows-
dc.subject.keywordOverall thermal transmittance of windows-
dc.description.isoatrue-
dc.subject.subareaComputer Science (miscellaneous)-
dc.subject.subareaGeography, Planning and Development-
dc.subject.subareaRenewable Energy, Sustainability and the Environment-
dc.subject.subareaEnvironmental Science (miscellaneous)-
dc.subject.subareaEnergy Engineering and Power Technology-
dc.subject.subareaHardware and Architecture-
dc.subject.subareaComputer Networks and Communications-
dc.subject.subareaManagement, Monitoring, Policy and Law-
Show simple item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Kim, Sun Sook Image
Kim, Sun Sook김선숙
Department of Architecture
Read More

Total Views & Downloads

File Download

  • There are no files associated with this item.