Ajou University repository

Switch open-fault detection for a three-phase hybrid active neutral-point-clamped rectifieroa mark
Citations

SCOPUS

16

Citation Export

DC Field Value Language
dc.contributor.authorKim, Sang Hun-
dc.contributor.authorKim, Seok Min-
dc.contributor.authorPark, Sungmin-
dc.contributor.authorLee, Kyo Beum-
dc.date.issued2020-09-01-
dc.identifier.issn2079-9292-
dc.identifier.urihttps://dspace.ajou.ac.kr/dev/handle/2018.oak/31624-
dc.description.abstractThis paper proposes a fault-detection method for open-switch failures in hybrid active neutral-point-clamped (HANPC) rectifiers. The basic HANPC topology comprises two SiC-based metal-oxide-semiconductor field-effect transistors (MOSFETs) and four Si insulated-gate bipolar transistors (IGBTs). A three-phase rectifier system using the HANPC topology can produce higher efficiency and lower current harmonics. An open-switch fault in a HANPC rectifier can be a MOSFET or IGBT fault. In this work, faulty cases of six different switches are analyzed based on the current distortion in the stationary reference frame. Open faults in MOSFET switches cause immediate and remarkable current distortions, whereas, open faults in IGBT switches are difficult to detect using conventional methods. To detect an IGBT fault, the proposed detection method utilizes some of the reactive power in a certain period to make an important difference, using the direct-quadrant (dq)-axis current information derived from the three-phase current. Thus, the proposed detection method is based on three-phase current measurements and does not use additional hardware. By analyzing the individual characteristics of each switch failure, the failed switch can be located exactly. The effectiveness and feasibility of the proposed fault-detection method are verified through PSIM simulations and experimental results.-
dc.description.sponsorshipFunding: This work was supported by the Korea Institute of Energy Technology Evaluation and Planning (KETEP) and the Ministry of Trade, Industry & Energy (MOTIE) of the Republic of Korea. (No. 20182410105160, No. 20206910100160).-
dc.description.sponsorshipThis work was supported by the Korea Institute of Energy Technology Evaluation and Planning (KETEP) and the Ministry of Trade, Industry & Energy (MOTIE) of the Republic of Korea. (No. 20182410105160, No. 20206910100160). Acknowledgments: Authors thank our Power Electronics Laboratory colleagues of Electrical & Computer Engineering Department, Ajou University, South Korea.-
dc.language.isoeng-
dc.publisherMDPI AG-
dc.titleSwitch open-fault detection for a three-phase hybrid active neutral-point-clamped rectifier-
dc.typeArticle-
dc.citation.endPage21-
dc.citation.startPage1-
dc.citation.titleElectronics (Switzerland)-
dc.citation.volume9-
dc.identifier.bibliographicCitationElectronics (Switzerland), Vol.9, pp.1-21-
dc.identifier.doi10.3390/electronics9091437-
dc.identifier.scopusid2-s2.0-85093893982-
dc.identifier.urlhttps://www.mdpi.com/2079-9292/9/9/1437/pdf-
dc.subject.keywordAC-DC rectifier system-
dc.subject.keywordActive neutral-point-clamped inverter-
dc.subject.keywordCurrent vector angle-
dc.subject.keywordFault detection method-
dc.subject.keywordOpen-switch fault-
dc.subject.keywordReactive current injection-
dc.description.isoatrue-
dc.subject.subareaControl and Systems Engineering-
dc.subject.subareaSignal Processing-
dc.subject.subareaHardware and Architecture-
dc.subject.subareaComputer Networks and Communications-
dc.subject.subareaElectrical and Electronic Engineering-
Show simple item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

 Lee, Kyo-Beum Image
Lee, Kyo-Beum이교범
Department of Electrical and Computer Engineering
Read More

Total Views & Downloads

File Download

  • There are no files associated with this item.