Ajou University repository

Fault diagnosis of open-switch failure in a grid-connected three-level Si/Sic hybrid ANPC inverteroa mark
  • Kwon, Bong Hyun ;
  • Kim, Sang Hun ;
  • Kim, Seok Min ;
  • Lee, Kyo Beum
Citations

SCOPUS

21

Citation Export

DC Field Value Language
dc.contributor.authorKwon, Bong Hyun-
dc.contributor.authorKim, Sang Hun-
dc.contributor.authorKim, Seok Min-
dc.contributor.authorLee, Kyo Beum-
dc.date.issued2020-03-01-
dc.identifier.issn2079-9292-
dc.identifier.urihttps://dspace.ajou.ac.kr/dev/handle/2018.oak/31193-
dc.description.abstractA diagnostic method for an open-circuit switch failure in a hybrid active neutral-point clamped (HANPC) inverter is proposed in this paper. The switching leg of the HANPC inverter consists of four silicon insulated gate bipolar transistors and two silicon carbide metal-oxide-semiconductor field-effect transistors to achieve higher efficiency and power density compared to conventional neutral-point clamped inverters. When an open-circuit failure occurs in a switching device, the output current is severely distorted, causing damage to the inverter and the connected loads. The proposed diagnostic method aims to detect the open-switch failure and protect the related devices without additional sensors or circuits. The faulty conditions of six different switches are investigated based on the current distortion in the stationary reference frame. By analyzing the individual characteristic of each switch failure, it is possible to detect the exact location of the failed switch in a short period. The effectiveness and feasibility of the proposed fault-diagnostic method are verified using simulation and experimental results.-
dc.description.sponsorshipThis work was supported by the Korea Institute of Energy Technology Evaluation and Planning (KETEP) and the Ministry of Trade, Industry & Energy (MOTIE) of the Republic of Korea. (No. 20171210201100, No.20182410105160) .-
dc.description.sponsorshipFunding: This work was supported by the Korea Institute of Energy Technology Evaluation and Planning (KETEP) and the Ministry of Trade, Industry & Energy (MOTIE) of the Republic of Korea. (No. 20171210201100, No.20182410105160)-
dc.language.isoeng-
dc.publisherMDPI AG-
dc.titleFault diagnosis of open-switch failure in a grid-connected three-level Si/Sic hybrid ANPC inverter-
dc.typeArticle-
dc.citation.titleElectronics (Switzerland)-
dc.citation.volume9-
dc.identifier.bibliographicCitationElectronics (Switzerland), Vol.9-
dc.identifier.doi10.3390/electronics9030399-
dc.identifier.scopusid2-s2.0-85081197992-
dc.identifier.urlhttps://www.mdpi.com/2079-9292/9/3/399/pdf-
dc.subject.keywordActive neutral-point clamped inverters-
dc.subject.keywordFault diagnosis-
dc.subject.keywordGrid-connected systems-
dc.subject.keywordOpen-circuit switch failure-
dc.subject.keywordSilicon carbide devices-
dc.description.isoatrue-
dc.subject.subareaControl and Systems Engineering-
dc.subject.subareaSignal Processing-
dc.subject.subareaHardware and Architecture-
dc.subject.subareaComputer Networks and Communications-
dc.subject.subareaElectrical and Electronic Engineering-