Ajou University repository

Smartphone-integrated urinary CTX-II immunosensor based on wavelength filtering from chromogenic reaction
Citations

SCOPUS

7

Citation Export

DC Field Value Language
dc.contributor.authorKim, Saemi-
dc.contributor.authorChun, Hyeong Jin-
dc.contributor.authorLee, Kyung Won-
dc.contributor.authorYoon, Hyun C.-
dc.date.issued2020-02-15-
dc.identifier.urihttps://dspace.ajou.ac.kr/dev/handle/2018.oak/31085-
dc.description.abstractThe integration of smart IT devices and biochemical assays with optical biosensing technology facilitates the development of efficacious optical biosensors for many practical diagnostic fields, owing to their minimized use of high-technical electronic components and simple operation. Herein, we introduced a simple optical biosensing system based on the specific wavelength filtering principle and count-based analysis method. The developed system uses a smartphone with a paper-based signal guide and a biosensing channel. The paper-based signal guide was prepared by printing red patterns of various brightness on a black background. Given that a blue product is generated as a result of horseradish peroxidase (HRP)-based enzymatic reaction in the biosensing channel, the channel could be used as a blue filter that absorbs red light. When red light reflected from the red pattern is absorbed by the channel, the pattern appears black. As such, the color of the patterns is assimilated with the black background, so it seems to disappear. Consequently, the amount of blue product relative to the concentration of the target analyte can be measured by counting the number of observed patterns on the paper-based signal guide. In this study, the concentration of urinary C-telopeptide fragment of type II collagen (uCTX-II, 0–10 ng/mL) was measured using the developed system without complicated equipment. In addition, the quantitative analysis of uCTX-II in the real urine sample was successfully performed. Therefore, we expect that the developed optical transducing system could be practically used for point-of-care testing (POCT) diagnosis under resource-limited environmental conditions.-
dc.description.sponsorshipThis work was supported by the Creative Materials Discovery Program ( NRF-2019M3D1A1078943) and the Priority Research Centers Program ( NRF-2019R1A6A1A11051471 ) funded by the National Research Foundation of Korea (NRF) . We also acknowledge the support from the Technology Innovation Program ( 10051409 ) funded by the Ministry of Trade, Industry and Energy (MOTIE, Korea) . Appendix A-
dc.language.isoeng-
dc.publisherElsevier Ltd-
dc.subject.meshArtificial urines-
dc.subject.meshChromogenic reaction-
dc.subject.meshCount-based analysis-
dc.subject.meshEnvironmental conditions-
dc.subject.meshFiltering effects-
dc.subject.meshHorseradish peroxidase-
dc.subject.meshPoint-of-care testing-
dc.subject.meshWavelength filtering-
dc.subject.meshBiosensing Techniques-
dc.subject.meshCollagen Type II-
dc.subject.meshColorimetry-
dc.subject.meshEquipment Design-
dc.subject.meshHumans-
dc.subject.meshLimit of Detection-
dc.subject.meshPaper-
dc.subject.meshPeptide Fragments-
dc.subject.meshPoint-of-Care Testing-
dc.subject.meshSmartphone-
dc.titleSmartphone-integrated urinary CTX-II immunosensor based on wavelength filtering from chromogenic reaction-
dc.typeArticle-
dc.citation.titleBiosensors and Bioelectronics-
dc.citation.volume150-
dc.identifier.bibliographicCitationBiosensors and Bioelectronics, Vol.150-
dc.identifier.doi10.1016/j.bios.2019.111932-
dc.identifier.pmid31791877-
dc.identifier.scopusid2-s2.0-85077383407-
dc.identifier.urlwww.elsevier.com/locate/bios-
dc.subject.keywordArtificial urine-
dc.subject.keywordCount-based analysis-
dc.subject.keywordFiltering effect-
dc.subject.keywordPoint-of-care testing (POCT)-
dc.subject.keywordSmartphone-based biosensor-
dc.subject.keyworduCTX-II detection-
dc.description.isoafalse-
dc.subject.subareaBiotechnology-
dc.subject.subareaBiophysics-
dc.subject.subareaBiomedical Engineering-
dc.subject.subareaElectrochemistry-
Show simple item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Yoon, Hyun Chul Image
Yoon, Hyun Chul윤현철
College of Bio-convergence Engineering
Read More

Total Views & Downloads

File Download

  • There are no files associated with this item.