Ajou University repository

In-situ fatigue monitoring procedure using nonlinear ultrasonic surface waves considering the nonlinear effects in the measurement systemoa mark
  • Dib, Gerges ;
  • Roy, Surajit ;
  • Ramuhalli, Pradeep ;
  • Chai, Jangbom
Citations

SCOPUS

8

Citation Export

DC Field Value Language
dc.contributor.authorDib, Gerges-
dc.contributor.authorRoy, Surajit-
dc.contributor.authorRamuhalli, Pradeep-
dc.contributor.authorChai, Jangbom-
dc.date.issued2019-06-01-
dc.identifier.urihttps://dspace.ajou.ac.kr/dev/handle/2018.oak/30562-
dc.description.abstractSecond harmonic generation using nonlinear ultrasonic waves have been shown to be an early indicator of possible fatigue damage in nuclear power plant components. This technique relies on measuring amplitudes, making it highly susceptible to variations in transducer coupling and instrumentation. This paper proposes an experimental procedure for in-situ surface wave nonlinear ultrasound measurements on specimen with permanently mounted transducers under high cycle fatigue loading without interrupting the experiment. It allows continuous monitoring and minimizes variation due to transducer coupling. Moreover, relations describing the effects of the measurement system nonlinearity including the effects of the material transfer function on the measured nonlinearity parameter are derived. An in-situ high cycle fatigue test was conducted using two 304 stainless steel specimens with two different excitation frequencies. A comprehensive analysis of the nonlinear sources, which result in variations in the measured nonlinearity parameters, was performed and the effects of the system nonlinearities are explained and identified. In both specimens, monotonic trend was observed in nonlinear parameter when the value of fundamental amplitude was not changing.-
dc.description.sponsorshipThis work was supported under the research project on online monitoring and prognostics for nuclear power plants by the \ Korea Institute of Energy Technology Evaluation and Planning(KETEP) granted financial resource from the Ministry of Trade, Industry and Energy, Republic of Korea (No. 20128540010020 ).-
dc.language.isoeng-
dc.publisherKorean Nuclear Society-
dc.titleIn-situ fatigue monitoring procedure using nonlinear ultrasonic surface waves considering the nonlinear effects in the measurement system-
dc.typeArticle-
dc.citation.endPage876-
dc.citation.startPage867-
dc.citation.titleNuclear Engineering and Technology-
dc.citation.volume51-
dc.identifier.bibliographicCitationNuclear Engineering and Technology, Vol.51, pp.867-876-
dc.identifier.doi10.1016/j.net.2018.12.003-
dc.identifier.scopusid2-s2.0-85060601853-
dc.identifier.urlhttp://www.kns.org/-
dc.subject.keywordHigh-cycle fatigue-
dc.subject.keywordIn-situ monitoring-
dc.subject.keywordNonlinear ultrasound-
dc.subject.keywordSurface wave-
dc.description.isoatrue-
dc.subject.subareaNuclear Energy and Engineering-
Show simple item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Chai, Jang Bom Image
Chai, Jang Bom채장범
Department of Mechanical Engineering
Read More

Total Views & Downloads

File Download

  • There are no files associated with this item.