Ajou University repository

Common-mode voltage reduction for inverters connected in parallel using an mpc method with subdivided voltage vectors
  • Park, Joon Young ;
  • Sin, Jiook ;
  • Bak, Yeongsu ;
  • Park, Sung Min ;
  • Lee, Kyo Beum
Citations

SCOPUS

2

Citation Export

DC Field Value Language
dc.contributor.authorPark, Joon Young-
dc.contributor.authorSin, Jiook-
dc.contributor.authorBak, Yeongsu-
dc.contributor.authorPark, Sung Min-
dc.contributor.authorLee, Kyo Beum-
dc.date.issued2018-05-01-
dc.identifier.urihttps://dspace.ajou.ac.kr/dev/handle/2018.oak/30183-
dc.description.abstractThis paper presents a model predictive control (MPC) method to reduce the common-mode voltage (CMV) for inverters connected in parallel, which increase the capacity of energy storage systems (ESSs). The proposed method is based on subdivided voltage vectors, and the resulting algorithm can be applied to control the inverters. Furthermore, we use more voltage vectors than the conventional MPC algorithm; consequently, the quality of grid currents is improved. Several methods were proposed in order to reduce the CMV appearing during operation and its adverse effects. However, those methods have shown to increase the total harmonic distortion of the grid currents. Our method, however, aims to both avoid this drawback and effectively reduce the CMV. By employing phase difference in the carrier signals to control each inverter, we successfully reduced the CMV for inverters connected in parallel, thus outperforming similar methods. In fact, the validity of the proposed method was verified by simulations and experimental results.-
dc.language.isoeng-
dc.publisherKorean Institute of Electrical Engineers-
dc.subject.meshCapacity of energies-
dc.subject.meshCarrier signals-
dc.subject.meshCommon mode voltage-
dc.subject.meshGrid connected inverters-
dc.subject.meshParallel-connected inverters-
dc.subject.meshPhase difference-
dc.subject.meshPhase-shifted carriers-
dc.subject.meshTotal harmonic distortion (THD)-
dc.titleCommon-mode voltage reduction for inverters connected in parallel using an mpc method with subdivided voltage vectors-
dc.typeArticle-
dc.citation.endPage1222-
dc.citation.startPage1212-
dc.citation.titleJournal of Electrical Engineering and Technology-
dc.citation.volume13-
dc.identifier.bibliographicCitationJournal of Electrical Engineering and Technology, Vol.13, pp.1212-1222-
dc.identifier.doi10.5370/jeet.2018.13.3.1212-
dc.identifier.scopusid2-s2.0-85045428696-
dc.identifier.urlhttp://www.jeet.or.kr/ltkPSWeb/pub/pubfpfile.aspx?ppseq=2065-
dc.subject.keywordCommon-mode voltage-
dc.subject.keywordGrid-connected inverters-
dc.subject.keywordModel predictive control-
dc.subject.keywordParallel-connected inverters-
dc.subject.keywordPhase-shifted carrier-
dc.subject.subareaElectrical and Electronic Engineering-
Show simple item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

 Lee, Kyo-Beum Image
Lee, Kyo-Beum이교범
Department of Electrical and Computer Engineering
Read More

Total Views & Downloads

File Download

  • There are no files associated with this item.