Ajou University repository

Measurement of temperature and rotational velocity of main ion in KSTAR by Charge Exchange Spectroscopy
  • 김정훈
Citations

SCOPUS

0

Citation Export

Advisor
박지용
Affiliation
아주대학교 일반대학원
Department
일반대학원 에너지시스템학과
Publication Year
2014-02
Publisher
The Graduate School, Ajou University
Keyword
KSTARmain ionCharge Exchange Spectroscopy
Description
학위논문(석사)--아주대학교 일반대학원 :에너지시스템학과,2014. 2
Alternative Abstract
For the study of plasma physics, the measurement of the ion temperature and plasma rotation velocity profiles are of fundamental importance in controlled fusion research, several diagnostics have been developed to measure this quantity. Among them, The Charge Exchange Spectroscopy(CES) has been used as a diagnostic tool for measuring the concentrations of impurity ions and studying impurity behaviors in fusion plasma. In general, The CES is applied to investigate spectral lines emanated from light impurities such as C, He, Ne, Be, etc. Although measurement of the properties of the main ion species (H or D) is of primary importance in fusion plasma, spectral lines from impurity have been preferred due to the complexities and difficulties on the analysis of the spectral lines from main ions. Practically, main ion temperature is assumed to be same with impurity temperature when the collision frequency between main ions and impurities with help enough but rotation velocity of main ion is expected to be the dissimilar with impurity rotation velocity. In addition, measurement of impurity has restrictions depending on what is the material of the Tokamak. Consequentially, direct measurement of main ion properties is still demanded since these approaches cannot be validated in some cases. In 2012, 2013 KSTAR experimental campaign, the main ion spectral lines has been investigated under the framework of the development of main ion CES system. Also, in order to overcome difficulties in analyzing spectral information around deuterium and hydrogen lines at 656.1 nm and 656.3 nm from the main ions of high temperature plasma in KSTAR, a two-grating spectrometer system is built using two concave mirrors. The spectral resolution is achieved up to 0.03Å. Simulation work for predicting charge exchange spectral lines for hydrogen and deuterium in some cases has been don for assessing the requirement for the spectrometer for main ion CES. The measured active charge-exchange signal can be fitted with two-Gaussian functions by means of a nonlinear least-squares fitting.
Language
eng
URI
https://dspace.ajou.ac.kr/handle/2018.oak/12577
Fulltext

Type
Thesis
Show full item record

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Total Views & Downloads

File Download

  • There are no files associated with this item.