Ajou University repository

스위치드 릴럭턴스 전동기의 고장진단 및 허용제어 기법
  • 노학승
Citations

SCOPUS

0

Citation Export

Advisor
이교범
Affiliation
아주대학교 일반대학원
Department
일반대학원 전자공학과
Publication Year
2014-02
Publisher
The Graduate School, Ajou University
Description
학위논문(석사)--아주대학교 일반대학원 :전자공학과,2014. 2
Alternative Abstract
This paper proposes a fault identification method for the asymmetric converter in a switched reluctance motor (SRM). The identification method include fault diagnosis and tolerance control. The switches in an asymmetric converter and gate drivers are easily destroyed while the role of these components is important. When a fault is emerged on the switches it can cause a primary and secondary problem to the system. In this paper, the diagnostic method relies on analyzing the Park’s vector representation of the current variation from short and open faults. The fault tolerance method utilizes the characteristics of the SRM. It can diagnose and tolerate the fault without additional equipment. Simulations and experiments have been performed on the 1.5kW SRM drive and its results are presented to verify the validity of the proposed method.